Redundant Hosting at our Hardened Data Centers

 

Business class web hosting goes beyond renting excess disk space on a local web server. Your business requires a data center that was designed with the business customer in mind.

 

All BEST E-Systems hosted websites are resident on servers located in two state-of-the-art data centers, offering complete redundancy in power, HVAC, fire suppression, network connectivity, and security. Physical maintenance, security, and connectivity are managed by The Planet.

 

Why did we choose to outsource these critical services?

 

Because our business customers deserve the additional security, reliability, and redundancy offered by a professionally managed commercial data center. Compare our solution to the typical hosting company which is sharing space on the server in their back room.  A flood, a power surge, or even a good stiff wind will take their servers (and your website and email) down. Your service will become available whenever the local utilities or computer parts distributor can get them back up and running. 

 

Our clients deserve more than that. Every one of our customers, from the smallest startup to the largest corporation, deserves to know that their website and email are secure and available, physically housed within a facility designed specifically to host the websites and application servers of the world's largest corporations.

 

Facility Specifications

 

The datacenter facilities sit atop multiple power grids driven by TXU electric, with PowerWare UPS battery backup power and dual diesel generators onsite. The HVAC systems are condenser units by Data Aire to provide redundancy in cooling coupled with ten managed backbone providers. Twelve more third party backbone providers are available in the building via cross connect. Fire suppression includes a pre-action dry pipe system including VESDA (Very Early Smoke Detection Apparatus) with over 700 smoke detectors between the two facilities.

 

Data Center 1

  • 60,000 sq. ft. facility
  • 35,000 sq. ft. of raised floor
  • (21) 26-ton Data Air AC units
  • Very Early Smoke Detection Apparatus (VESDA)
  • Pre-action dry pipe sprinkler system
  • Over 500 smoke detectors in an integrated system
  • Simplex security badge entry/exit on all doors to facility
  • Multiple TXU electrical grids
  • 4800 amps of 480v input power
  • 3 main transfer switches
  • (6) 500KVA Powerware UPS units with 90 batteries per unit
  • Standalone PDUs at each cabinet row
  • 1-megawatt generator (2000-gallon tank)
  • 1.5-megawatt generator (2200-gallon tank)
  • DataTrax monitoring software for all data center infrastructure

Data Center 2

  • 22,000 sq. ft. facility
  • 18,000 sq. ft. of raised floor
  • (12) 26-ton Data Air AC units
  • Very Early Smoke Detection Apparatus (VESDA)
  • Pre-action dry pipe sprinkler system
  • Over 220 smoke detectors in an integrated system
  • Simplex security badge entry/exit on all doors to facility
  • TXU fault tolerant electrical grid
  • 2000 amps of 480v input power
  • 1 main transfer switch
  • (2) 500KVA Powerware UPS units with 90 batteries per unit
  • Standalone PDUs at each cabinet row
  • 1.5-megawatt generator (2200-gallon tank)
  • DataTrax monitoring software for all data center infrastructure

Network Infrastructure

Our network architecture utilizes the Enterprise routing and switching engines from Juniper and Cisco. We utilize Juniper M20 routers as border routers, Cisco 6500 series switches in our distribution layer and Cisco 6500 switches in our aggregation layers, and Cisco 3500 and 2900 series switches at the customer layer. Our network is fully meshed and redundant with 11 backbone providers.
 
Network Building Fiber
  • Cisco Certified Network
  • Cisco 6500 series distribution routing switched
  • Cisco 6500 series aggregation switches for customer access
  • Juniper M20 border routers
  • 100% uptime SLA utilizing HSRP/BGP
  • OC48 SONET Ring - SBC
  • OC48 SONET Ring - Time Warner
  • OC48 SONET Ring - XO Communications
  • OC48 SONET Ring - MCI
  • OC48 SONET Ring - Looking Glass
  • OC48 SONET Ring - Broadwing
  
Backbone Carriers Access
  • 3 Gbps Direct Fiber - AboveNet
  • 3 Gbps Direct Fiber - AT&T
  • 1 Gbps Direct Fiber - Broadwing
  • 1 Gbps Direct Fiber - Dallas Public Peering
  • 2 Gbps Direct Fiber - Global Crossing
  • 3 Gbps Direct Fiber - Level3
  • 1 Gbps Direct Fiber - nLayer
  • 2 Gbps Direct Fiber - Sprint
  • 1 Gbps Direct Fiber - Time Warner
  • 1 Gbps Direct Fiber - UUNET
  • 1 Gbps Direct Fiber - Verio
  • T3 and T1 Access - EPGN
  • T3 and T1 Access - SBC
  • T3 and T1 Access - Time Warner
  • T3 and T1 Access - XO Communications
  • T3 and T1 Access - MCI